RTD Embedded Technologies, Inc. | www.rtd.com 13 COM16155ER/COM16155RER User’s Manual
3.3.2 JUMPERS
The following sections describe the jumper configuration options available on the COM16155. The default factory jumper settings are listed in
the following table:
1-2: +5.0V
2-3: +3.3V
Open for passive antennas
Pull-up or Pull-down for DIO0-7
1-2: Pull-up
2-3: Pull-down
No connect – Neither
Pull-up or Pull-down for DIO8-15
1-2: Pull-up
2-3: Pull-down
No connect – Neither
1-2: COM17045 Compatible
2-3: COM16155
1PPS on UART carrier detect
(COM16155 mode only)
1-2: Enables 1PPS on UART CD
2-3: Disable 1PPS on UART CD
JP6 & JP7: Base Address Jumpers
The base address selection jumpers (A3 through A8) allow you to set the base address of the first UART that connects to the GPS module and
the second UART that connects to the GSM module. Any software that accesses the board will do so through reads and writes to the I/O
address set by the jumpers. To function properly, the I/O address the software is expecting must match the base address set by the jumpers.
As shown in the figure below, A3 is located at the left end of the jumper block, while A8 is located at the right end:
The table on the following pages shows the possible base address settings for the COM16155. All base addresses are in hexadecimal. An ‘X’
indicates a closed jumper, while an empty cell indicates an open jumper.
Base Address
(Hexadecimal)
Komentarze do niniejszej Instrukcji